The research considers an hourly residential load demand with a daily average of 988kWh/day and investigates possible standalone systems, including solar panels (photovoltaic [PV]), wind turbines (WTs), diesel generator (DG), biogenerator (BG), and battery bank (Bat), to provide the load demand, for a case study located in Tabuk, Saudi Arabia, where the monthly solar radiation and wind speed are 5.74kWh/m2/day and 5.33m/s, respectively. In this study, enviroeconomic factors, including inflation and discount rates, capacity shortage and load demand, CO2 and SO2 penalties, diesel and biomass prices are considered, while they were not considered in the previous studies in Saudi Arabia. The results show that the net present cost and cost of energy of the optimized system are $1.03M and 0.178$/kWh, respectively. Additionally, the prices of diesel fuel and biomass have a significant impact on the CO2 emissions of the system, even with a 10% increase in the renewable fraction. The results of sensitivity analyses show that increasing the CO2 emission penalty from 20 to 80$/ton leads to a decrease in CO2 emissions by 50%. The effect of the initial cost of WT on the configuration of the optimal system is higher than that of PV, and increasing both prices significantly leads to an increase in CO2 emissions.DOI
https://doi.org/10.1002/ese3.7037Тип публикаций
Практическое значение
The practical significance of the study lies in the development and optimization of an autonomous hybrid energy system for a residential facility with a daily electricity demand of 988 kWh/day, based on solar photovoltaic panels, wind turbines, diesel and biogenerators, as well as battery storage systems. The obtained results make it possible to determine the most cost-effective system configuration with a minimum net present cost of $1.03 million and a cost of energy of $0.178/kWh. The study has practical value for the design of standalone power supply systems in regions with high solar irradiation and wind potential. The consideration of environmental and economic factors such as inflation, CO₂ and SO₂ emission penalties, diesel fuel and biomass prices improves the accuracy of energy system performance assessment and reduces environmental impact. The sensitivity analysis results show that increasing CO₂ emission penalties leads to a significant reduction in emissions, while changes in the cost of wind turbines and photovoltaic panels have a strong influence on system configuration and environmental performance. This makes the study useful for engineers, energy companies, and government organizations in developing strategies for transitioning to renewable energy sources and reducing carbon footprints.Квартиль
Источник квартиля
JCR (WoS)Impact Factor
3.4Количество цитирований
0Данный документ располагается в коллекциях
Международные публикации ученых SU
Web of Science
Файлы документа
Документ не загружен